Materials
· Luciferase Substrate:
 Luc1 Substrate (DTZ) (Meisen, Cat# CTCC-002-023)
 Luc2 Substrate (AkaLumine-HCl) (Meisen, Cat# CTCC-002-024)
 · DPBS (Dulbecco's Phosphate-Buffered Saline), without Ca2+ or Mg2+
·  Syringe Filter, 0.2µm
 

 
Substrate Preparation
1. Thaw the substrates at room temperature and dissolve in DPBS (no calcium or magnesium) to the suggested final concentration.
Luc1 Substrate (DTZ): 3 mM DTZ solution containing 8% glycerol, 10% ethanol, 10% hydroxypropyl-β-cyclodextrin, and 35% PEG-400 in sterile water;
Luc2 Substrate (AkaLumine-HCl): 15 mM AkaLumine-HCl in saline;
 
2. Inoculate lab animal according to one of the various methods detailed below. (Luc1 and Luc2 substrates are typically administered either intraperitoneally or intravenously.)
Suggested starting dose: 100µl of prepared substrates for a 20g mouse.
 
3. Wait 10-20 minutes before imaging for maximum luciferase signal plateau.
 
4. A kinetic study of luciferase should be performed for each animal model to determine the peak signal time and plateau phase.

Determining the Kinetic Curve
The kinetics of tissue biodistribution may be different for each animal model and experimental design. We recommend creating a kinetic curve for each system prior to conducting the experiment in order to determine the peak signal time for imaging the animal model after the substrate injection.
 
To generate a kinetic curve for luciferase activity in your model:
1. Inject the substrate via one of the proposed methods listed below (Intraperitoneal (IP) or Intravenous (IV)). If you need to sedate the animals before injection, be aware that it may slightly extend the kinetics (peak luciferase expression time). The biodistribution of Luc substrate may also be different depending on the route of administration.
 
2. For IP Injection
a. If you are able to inject into animals which are still awake, wait three minutes, then sedate by your method of choice (gas or injectable anesthesia).

b. Place sedated animals in imaging chamber and take the first image approximately five minutes post Luc substrate injection.
 
3. For IV Injection
a. Immediately sedate the animal ( if not already sedated ) by your method of choice (gas or injectable anesthesia).
 
b. Place sedated animals in imaging chamber and take the first image within first two minutes post substrate injection
 
4. Continue to take images every 5-10 minutes up to about 40-60 minutes for IP injected models (for IV injected models: image every 1-5 minutes up to 20-30 minutes) to generate a kinetic curve for luciferase expression in your model.
· Most injectable anesthesia will last 20-30 minutes and might require an additional dose for a full kinetic curve study!)
 
5. Choose the best time point to image your model from your kinetic curve. Many models reach their peak signal time approximately 10-20 minutes post IP injection and 2-5 minutes post IV injection.
 
Intraperitoneal Injection (IP) in mice
1. First locate the point of entry for the needle
 
2. Draw an imaginary line across the abdomen just above the knees (see image above).
 
3. The needle should be inserted along this line on the animal's right side and close to the midline. (The point of entry is cranial to and slightly medial of the last nipple in a female mouse.)
 
4. Inserting the needle on the mouse's right side avoiding the cecum, which is a large fluid-filled organ on the left side of the abdomen. The small intestines (on the right side) are less likely to be punctured by the needle.
 
5. Inserting the needle too far caudally or laterally from the insertion point shown above would risk making an injection into the rear leg which would injure the muscle tissue.
 
6. To perform an IP injection, the mouse must be well restrained so that it cannot move during the procedure. This avoids traumatizing the organs once the needle has entered the abdomen.
 
7. Restrain the mouse and tilt so that the head is facing downward and its abdomen is
exposed.
 
8. Thoroughly disinfect the injection site with 70% ethanol. 9. We recommend using
a 25-27-gauge needle for IP injections. Insert the needle into the abdomen at about
a 30-degree angle.
 
Intravenous Injection (IV) in mice
 

 
Restrain the mouse with physical or chemical restraint. Rotate the tail slightly to visualize vein. Disinfect injection site with 70% ethanol and insert the needle (27-30 gauge) into the vein at a slight angle. You will not be able to aspirate, instead inject slowly and watch for clearing of the lumen. Incorrect positioning will result in a slight bulge in the tail. If this occurs, remove needle and repeat process proximal to previous site. Upon completion, remove needle and apply pressure to injection site. Record the injection time to determine peak signal time.
發布者:浙江美森細胞科技有限公司
聯系電話:0571-86027729
E-mail:120977236@qq.com

用戶名: 密碼: 匿名 快速注冊 忘記密碼
評論只代表網友觀點,不代表本站觀點。 請輸入驗證碼: 8795
Copyright(C) 1998-2025 生物器材網 電話:021-64166852;13621656896 E-mail:info@bio-equip.com
主站蜘蛛池模板: 久久综合高清 | 久久久久久久99精品欧美产片 | 国产成人自拍网 | 日本同性老头 | 裸体男同自慰gay网站 | 成人精品天堂一区二区三区 | 日本一区视频在线 | 99久久久无码国产精品免费 | 熟妇人妻午夜寂寞影院 | 国产真实乱子伦精品视频 | 久久456 | 国产高潮又爽又刺激的视频 | 国产精品无码翘臀在线观看 | 中文在线免费看视频 | 性欧美videosex18嫩 | 欧美牲交a欧美牲交aⅴ免费真 | 四虎国产成人永久精品免费 | 99美剧| 日本成熟少妇高潮A片 | 国产a级黄色片 | 亚洲免费在线视频观看 | 欧美性受xxx黑人xyx性爽 | 日本国产欧美大码a视频 | 最新亚洲av日韩av二区 | 好吊妞www.84com只有这里才有精品 | 国产91高清视频 | 福利视频在线 | yellow在线观看免费观看大全 | 女人把腿张开让男人来桶 | 国产日产一区二区三区久久久久久 | 久久精品综合 | 国产精品精品视频 | 亚洲日韩一区二区 | 国产免费ab| 老女人综合网 | 老汉色av影院 | 台湾成人免费视频 | 天天躁日日躁狠狠躁性色AV | 小荡货好紧好爽A片视频 | 国产精品三区在线 | 日韩精品一区二区免费视频 |